Product Type:
Automatic urinal flushing system with infrared sensor
Areas of Application:
Gas stations, rest stops, public restrooms, schools
Conditions of Use: Danger from vandalism, frequent use
Features / Components:
- non-contact in-line urinal control with wall or ceiling sensor
- fixed electrical connection (230 V)
- flow limitation of 0.2 l/s removable to increase flow rate
- functions are factory preset
- automatic flush after 24 hours of non-use
- programming of special functions possible with data terminal
- item number: 6575
Technical Data:
- working pressure: 150 to 1000 kPa
- flow rate at 300 kPa (flow limiter): 0.2 l/s
- electrical connection: 230 VAC
- sensor range: maximum 15 m
- automatic flushing: 24 h (0 to 255 h)
- flushing delay: 60 s (0 to 255 s)
- flushing duration: 10 s (1 to 30 s)
- sensor cable: 6 m
- pressure drop at a flow rate of 0.2 l/s: 140 kPa
Price (without guarantee):
The price is available on request from the manufacturer / distributor.